93
Model C606 Operating Procedures
Step 8
Repeat step 3 with the sanitizing solution.
Step 9
Place disassembled parts on clean and sanitized
parts trays.
Step 10
Wipe all exterior surfaces of the freezer with a clean,
sanitized towel.
Step 11
Repeat steps 1 through 10 for the soft serve side
of the freezer.
Syrup System - Scheduled
Maintenance
Syrup Pump Tube Removal
Step 1
Remove the pick up tubes from the syrup
containers. Wipe the outside of the tubes with a
clean, sanitized towel.
For Syrup Bag System: Disconnect the syrup bag
fitting from each bag.
Step 2
Remove the syrup containers and the pump cover
tray from inside the cabinet.
Step 3
Place the pick up tubes in a pail of an approved 100
PPM cleaning solution (examples: Kay-5® or
Stera-Sheen®). USE WARM WATER AND
FOLLOW THE MANUFACTURER'S
SPECIFICATIONS. To avoid contamination, cover
the syrup containers with a plastic wrap.
For Syrup Bag System: Place the syrup hose with
the bag connection fitting in a pail of an approved
100 PPM cleaning solution (examples: Kay-5® or
Stera-Sheen®). USE WARM WATER AND
FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 4
Raise the retainer and remove the syrup valve from
the freezer door. Place the valve in a pail located
under the draw valve.
Step 5
Select the CALIBRATION symbol
on the control
panel to display the menu options.
Step 6
Touch the AUTO symbol
to move the arrow to
SYRUP PRIME. Touch the CALIBRATION symbol
again to display the SYRUP PRIME screen.
Step 7
Select the FLAVOR SELECT symbol
for the
corresponding syrup valve to start the flow of
cleaning solution through the syrup line.
Step 8
Allow the cleaning solution to flow until all of the
syrup is flushed from the line.
Step 9
Once the line is free of syrup, remove the pick up
tube from the cleaning solution and continue to run
the pump until the syrup line is free from liquid.
Select the FLAVOR SELECT symbol
to stop the
pump.
Step 10
Repeat steps 3 through 9 using an approved 100
PPM sanitizing solution (examples: Kay-5® or
Stera-Sheen®). USE WARM WATER AND
FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 11
Open the pump by pushing up on the hinged cover.
(See the arrow in Figure 237.)
Figure 237