46
10. Remove, clean and reinstall the long drip
pan through the front panel.
(See Figure 60.)
Figure 60
11. Remove, clean and reinstall the two short
drip pans in the rear panel.
12. Remove, clean and reinstall the two
notched drip pans in the left and right side
panels. (See Figure 61.)
Figure 61
13. Using a clean, sanitized towel, wip e down
the freezer door, front panel, the area
around the bottom of the freezer door,
and any other areas that demonstrate a
build-up of either moisture or food
substance.
The heat cycle will start at the AUTO HEAT
TIME setting in the Manager’s Menu.
(See page 81).
There are three phases of the heat cycle:
Heating, Holding and Cooling. Each phase
has a time limit. If any one of the three phases
fail to reach the proper temperatures within the
time limit, the cycle will automatically abort and
return to the STANDBY mode.
A failure message will appear on the vacuum
fluorescent display (VFD) to inform the
operator that the machine did not successfully
complete the heat treatment cycle. The
product may not be safe to serve. The freezer
will be locked out (softlock) of the AUTO
mode. The operator will be given the option of
selecting the HEAT symbol
which will begin
a new heat cycle, or touching the WASH
symbol
which will place the side(s) into the
OFF mode to allow a brush clean of the
machine.
Note: Once the heating cycle has started, it
cannot be interrupted. The heating cycle will
take a maximum of 4 hours to complete with
full hoppers.
DO NOT attempt to draw product or
disassemble the unit during the HEAT cycle.
The product is hot and under extreme
pressure.
When the heating cycle is complete, the
control will return to the STANDBY mode. The
STANDBY symbols
and will be
illuminated.
Downloaded from www.dlmanuals.com