EasyManua.ls Logo

Taylor McDonald's C602 - Page 49

Taylor McDonald's C602
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
Pump Tube Installation
1. Lubricate the o -rings on the syrup line
fittings with Taylor Lube HP.
Figure 64
2. Press the fittings into the new pump tube.
3. Install the clips into their respective
collars.
4. Using your hands, rotate the pump rollers
so they are in the 10 and 2 oclock
position.
5. Place the tube assembly into the pump
body. (Make sure the syrup lines are
pushed through the rear of the cabinet.)
6. Push down on the top of the pump to
close it.
7. Replace the pump cover tray and the
syrup containers.
8. Prime the syrup lines.
9. Calibrate the syrup system according to
the instructions on page 39.
Syrup Line Cleaning/Sanitizing - Weekly
1. Remove the syrup feed tubes from the
syrup containers. Wipe the outside of the
feed tubes with a clean, sanitized towel.
For Syrup Bag System: Disconnect each
syrup bag and clean the hose connector
fitting with a clean, sanitized towel.
2. Draw two gallons of McD All Purpose
Super Concentrate (APSC) (HCS)
cleaning solution from the sink
proportioner into a pail. Place the syrup
feed tubes in the pail.
For Syrup Bag System: Place the syrup
hose with the bag connection fitting in the
pail of McD All Purpose Super
Concentrate (APSC) (HCS).
3. Raise the retainer and remove the syrup
valve from the freezer door. Place the
valve in a pail located under the draw
valve.
4. Select the CALIBRATION symbol
on
the control panel to display the menu
options.
5. Touch the AUTO symbol
to move the
arrow to SYRUP PRIME. Touch the
CALIBRATION symbol
again to display
the SYRUP PRIME screen.
6. Select the FLAVOR SELECT symbol
for the corresponding syrup valve to start
the flow of McD All Purpose Super
Concentrate (APSC) (HCS) through the
syrup line.
7. Allow the McD All Purpose Super
Concentrate (APSC) (HCS) to flow until
all the syrup is flushed from the line.
8. Touch the FLAVOR SELECT symbol
to stop the flow of McD All Purpose
Super Concentrate (APSC) (HCS).
9. Repeat steps 2 - 8 using McD Sanitizer
(HCS) [1 packet in 2-1/2 gal. (9-1/2 liters)
of water = 100 PPM.]
10. Remove the syrup nose fitting from the
syrup valve by turning the cap
counter-clockwise.
11. Remove the duckbill valve and o-ring from
the syrup nose fitting.
12. Using the white end of the double-ended
brush, scrub the inside of the syrup nose
fitting and the syrup line fitting to remove
any residual particles.
13. Using a shake cup filled with McD
Sanitizer (HCS), rinse the syrup valve
fitting thoroughly.
14. Using a clean, sanitized towel, gently wipe
any syrup from the duckbill valve.
Downloaded from www.dlmanuals.com