30
Models PH71/PH84Operating Procedures
Open the draw valve and draw off the remaining
sanitizing solution.
10296
Figure 36
(Note: On the Model PH84, momentarily open the
center draw valve to sanitize the center door spout.)
Press the PUMP key to stop pump operation.
Figure 37
Remove the vinyl sanitizing tube from the air/mix
pump.
Step 9
Press the WASH key and close the draw valve(s).
Figure 38
Note: Be sure your hands are clean and sanitized
before going on in these instructions.
Step 10
Place the agitator on the agitator housing.
Figure 39
Note: If agitator should stop turning during normal
operation, with sanitized hands, remove the agitator
from the agitator housing and brush clean with
sanitizing solution. Install the agitator back onto the
agitator housing.