39
Models PH71/PH84 Important: Operator Checklist
081111
The Air/Mix Pump Checklist
j 1. Dispose of o-rings and check rings if they are
worn, torn, or fit too loosely, and replace with
new ones.
j 2. Follow lubricating procedures carefully. DO
NOT lubricate check rings.
j 3. To avoid nicks and cracks, handle plastic pump
parts with care.
j 4. Be sure the air/mix pump is properly attached to
the drive hub, or severe and costly damage may
occur.
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by
following certain precautions, particularly if the
building is to be left unheated and subject to freezing
conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on spring in water valve. Use
air pressure on the outlet side to blow out any water
remaining in the condenser. This is extremely
important. Failure to follow this procedure may cause
severe and costly damage to the refrigeration system.
Your local Taylor Distributor can perform this service
for you.
Wrap detachable parts of the freezer such as beater,
blades, drive shaft, and freezer door, and place in a
protected dry place. Rubber trim parts and gaskets
can be protected by wrapping with moisture-proof
paper. All parts should be thoroughly cleaned of dried
mix or lubrication accumulations which attract mice
and other vermin.