52 Chapter 7 - Parameters Description User Manual
IPA
CODE NAME
PARAMETER PICK LIST
DESCRIPTION
[CODE]
FUNCTION
DESCRIPTION
DEFAULT
MIN
MAX
UNIT
VARIATION
P.324
P.325
P.340
P.341
P.342
P.343
P.360
P.380
P.381
P.382
P.383
P.400
P.410
P.420
P.421
P.422
Autocap V scan t
Autocap spd src
Undervoltage thr
Max pwrloss time
UV alarm storage
UV Trip mode
OV prevention
Autoreset
attmps
Autoreset clear
Autoreset delay
Autores flt rly
Ext fault mode
Ph Loss detec
en
Volt reduc mode
V reduction fact
V fact mult src
Voltage scanning time
during Pick Up
Source of the reference for
Pick Up function
Undervoltage threshold
Restart time from
undervoltage
Enabling of undervoltage
alarm storage
Undervoltage tripping mode
Automatic PickUp enabling
after Overvoltage
Number of autoreset
attempts
En. automatic reset of
autorestart attempts
Autoreset time delay
Alarm relay contacts
behaviour during autoreset
External fault mode
Phase Loss detection
enabling
Voltage reduction mode
Output voltage reduction
factor
Source of voltage
reduction factor multiplier
[0] Frequency ref
[1] Max freq ref
[2] Last freq ref
[3] Encoder
[0] Disable
[1] Enable
[0] Disabled
[1] CoastThrough
[2] Emg stop
[0] Disable
[1] Enable
[0] OFF
[1] ON
[0] Alm alw,No AR
[1] Alm run,No AR
[2] Alm alw, ARes
[3] Alm run,
ARes
[0] Disable
[1] Enable
[0] Always
[1] Steady state
[0] Null
[1] Analog inp 1
[2] Analog inp 2
[3] Analog inp 3
From active frequency
reference
From the Max fre ref
parameter
From freq. set desired
From encoder
Function disabled
Coast Through mode
Emergency stop mode
- Drive in alarm
Alarm always active
Alarm autoreset is not
possible.
- Drive in alarm
Alarm active only with
running motor.
Alarm autoreset is not
possible.
- Drive in alarm
Alarm always active
Alarm autoreset is
possible.
- Drive in alarm
Alarm active only with
running motor
Alarm autoreset is
possible.
Always
Costant speed only
Null
Analog input 1
Analog input 2
Analog input 3
0.2
0
0
0
1
0
1
0
10
5
1
0
1
0
100
0
0.1
0
40
0
0
0
0
0
0
0.1
0
0
0
0
10
0
V
% of
P.0 61
sec
min
sec
% of
P.0 61
25
3
80
25
1
2
1
255
250
50
1
3
1
1
100
3
0.1
0.1
459
460
462
463
464
491
465
466
467
468
469
470
492
471
472
473
Autocapture function
Undervoltage Config
Overvol. Config
Autoreset Config
External Fault ConfigVoltage Reductuction Config