CHAPTER 2 GENH SPECIFICATIONS
2.1 OUTPUT RATING
2.2 INPUT CHARACTERISTICS
1. Input voltage/freq. (*3)AC range (*13)
2.Input current (at 100/200Vac)
3.Power Factor
4.Efficiency (*4)
5.Inrush current at 100/200V
---
A
---
%
A
85~265Vac continuous , 47~63Hz,single phase.
10.5/5
0.99@100/200Vac , rated output power.
Less than 25A.
V6 812.5 20 30 40 60 80 100 150 300
600
76/78 77/80 81/84 82/85 82/85 83/87
83/87
83/87
83/87
83/87 83/87 83/87
2.5 ANALOG PROGRAMMING AND MONITORING
1.Vout voltage programming
2.Iout voltage programming
3.Vout resistor programming
4.Iout resistor programming
5.On/off control
6.Output current monitor
7.Output voltage monitor
8.Power supply OK signal
9.Parallel operation
10.Series operation
11.CV/CC indicator
12.Enable/Disable
13.Local/Remote analog control
14.Local/Remote analog indicator
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity: ±0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity: ±1% of rated Iout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: ±1% of rated Vout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: ±1.5% of rated Iout.
By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.
0~5V or 0~10V, user selectable. Accuracy: 1%.
0~5V or 0~10V, user selectable. Accuracy : 1%.
4~5V-OK, 0V-Fail. 500ohm series resistance.
Possible, up to 4 units in master/slave mode with single wire current balance connection.
Possible (with external diodes), up to 2 units.
Open collector. CC mode: On, CV mode: Off. Maximum voltage: 30V, maximum, sink current: 10mA.
Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V.
By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local.
Open co lector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: mA.l 10
2.3 CONSTANT VOLTAGE MODE
1.Max. Line regulation (*5)
2.Max Load regulation (*6)
3.Ripple and noise (p-p , 20MHz) (*10)
4.Ripple r.m.s., 5Hz~1MHz (*10)
5.Temperature coefficient
6.Temperature drift
7.Rem. sense compensation/wire
8.Up-prog. response time, 0~Vomax(*9)
9.Down-prog. response time: Full load
No load
10.Transient response time
11.Hold-up time
V
6812.5 20 30 40 60 80 100 150 300 600
---
---
mV
mV
---
V
mS
mS
mS
mS
PPM/C
0.01% of rated output voltage +2mV
0.01% of rated output voltage +2mV
60
8
50
6
60
7
60
7.5
50
6
60
7
60
7
75
7
75
8
75
8
130
20
300
60
50PPM/ from rated output voltage, following 30 minutes warm-up.
O
C
0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
11
1
1 1.5 2 345555
80 150
10
50 80 150
500
600
700 800 900 1000
1500
2000 2500 4000
More than 20mS, 100Vac, rated output power.
1100
1200
Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated
output current.
Output set-point: 10~100%.
Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
250
250
1.Rated output voltage ( 1)*
2.Rated output current (*2)
3.Rated output power
V
A
W
6
100
600
8
90
720
12.5
60
750
20
38
760
30
25
750
40
19
760
60
12.5
750
80
9.5
760
100
7.5
750
150
5
750
300
2.5
750
600
1.3
780
MODEL
GENH
6-100
8-90
12.5-60
20-38
30-25
40-19 60-12.5
80-9.5
100-7.5
150-5
300-2.5
600-1.3
V6 812.5 20 30 40 60 80 100 150 300
600
2.4 CONSTANT CURRENT MODE
1.Max. Line regulation (*5)
2.Max. Load regulation (*7)
3.Ripple r.m.s. 5Hz~1MHz (*8)
4.Temperature coefficient
5.Temperature drift
6.Warm up drift
---
---
---
---
mA
PPM/ C
O
0.01% of rated output current +2mA
0.02% of rated output current +5mA
70PPM/ C from rated output current, following 30 minutes warm-up.
O
0.01% of rated Iout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
200 1 08 110
50
45
30
38 29
23
8
64
9
Less than 0.1% rated output current over 30 minutes following power on or output voltage change or load
current change.
9