EasyManua.ls Logo

TEC MA-1650-4 Series - Page 138

Default Icon
228 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 135 -
EO3-11070
MA-1650-4 SERIES
|General Unit Weight Code| [AT/TL]
Deletion of Link-PLU Tables
CONDITION Any time outside a sale
OPERATION Mode Lock: SET
[ITEM CORR]
25 [X] or |Link-PLU Table No.| [ST] [AT/TL]
[VOID]
TARE TABLE AND GENERAL UNIT WEIGHT SETTING (Submode 26)
In the PLU TABLE PROGRAMMING operation (Submode 4), some of Scale-compulsory PLUs may be set with
a Tare Table No. The actual tare weight is set to each Tare Table here. Also, the General Unit Weight is set here
so that the Unit Weight may be effective to scale items entered through departments or PLUs without any Individual
Unit Weight designation.
CONDITION Any time outside a sale
OPERATION Mode Lock: SET
26 [X] |Tare Table No.| [ST] |Tare Weight| [#]
Repeat for othr tables to be deleted.
Repeat for other tables.
1 to 9
*
0 to 999
(Unit: 1/100 LB or gram.
Example: enter 13 for 0.13 LB.)
*(For sequentially programming
tables, the Table No. specifica-
tion can be skipped.)
1 to 11
LB unit Kg unit
1: 1 LB 1 Kg
9: 9 LB 9 Kg
10: 1/2 LB 100 g
11: 1/4 LB Not applicable
........
........
........
Only to set the
General Unit
Weight
** Only to set the Tare Weight
**
NOTE: The initial value for the General Unit Weight is set to Code 1 (1LB or 1Kg).