- 96 -
EO3-11070B
MA-1650-4 SERIES
Address No. Description of Programming Contents
-- Continued --
3) The linkage is effective in a sale only for one Head-link PLU and one
Sub-link PLU. If the Sub-link PLU is further programmed with
another Sub-link PLUs (with a Link-PLU Table No.), the third PLU will
not automatically entered.
4) It is possible to set multiple PLUs as Head-link to one Sub-link PLU.
(In Example 1 described above, it may be extended to have more
Head-link PLUs of similar items such as 7-up, which also link to the
Bottle Deposit of the same amount.)
5) Repeat, Item Correct, Dollar Discount, Vendor Coupon, Bottle Re-
turn, %+, or %- operations are not accepted for PLU-to-PLU link
entries. But Return Merchandise or Void operation is possible for the
Head-link (and the Sub-link PLU will be processed as returned or
voided item automatically, in this case).
6) The Sub-link PLU may be operated for sales entries, skipping the
Head-link PLU, without affecting the Head-link PLU sales memory.
7) Multiplication is possible on the Head-link PLU, and then the Sub-link
PLU will automatically be multiplied with the same quantity.
8) Modifier Keys (such as [SI/M]) will be effective for the Head-link PLU
item only, and the modification will be disregarded for the Sub-link
PLU.
9) When an error occurs at the Sub-link PLU, only the Head-link PLU
is entered but not the Sub-link PLU. (Errors such as Multiplication
Product Over-limit Error, the Sub-link PLU has not been opened, the
sale subtotal will turn into negative, etc.)
10) When the Sub-link is a negative PLU, a Return Merchandise or Void
entry through the Head-link PLU is not possible.
11) None of Scale-Compulsory PLUs should be linked as Sub-link to
another PLU of Head-link. An error will result on the Head-link item
entry attempt in this case.
12) When a price-change entry is made (using the [PR OPEN] or
[OPEN] key) through the Head-link PLU, the Sub-link PLU will
always require a manual amount entry (through [AMT]) even when
the Sub-link is a preset-price PLU.
13) PLU with the Age Limit Status programmed cannot be used for Link-
PLU.
-- Continued on next page --
(Revision Date: Aug. 11, ‘98)
(10)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TEC MA-1650-4 Series and is the answer not in the manual?

TEC MA-1650-4 Series Specifications

General IconGeneral
BrandTEC
ModelMA-1650-4 Series
CategoryCash Register
LanguageEnglish

Related product manuals