6. MAIN UNIT REPLACEMENT EO18-11006A
6.10 Replacing the Journal Printer Unit
6-19
5) Remove the two screws which secure the Journal Printer Unit to the Printer Base R, then remove the
Journal Printer Unit from the Printer Base R.
5) Replace the Journal Printer Unit with a new one, and then reassemble in the reverse order of removal.
6) Make a printer test in the diagnostic test to check the operation of the new printer. (Refer to Section 3.2
Print Test (“H” & All characters).)
NOTE: When reassembling, secure the Printer PWB Plate which supports the PRCN PC Board Ass’y and the
Printer Base R together with the screw so that the Printer Base R should be under the Printer PWB
Plate.
Screw
Printer Base R
Printer Base R
Printer PWB Plate