2. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-11006A
2.1 KRDC-600-QM-R (for QP model only)
2- 3
7) Secure the remote drawer harness onto the
bottom of the ECR with the option cable clamp
and screw as shown in the figure. At this time,
secure the earth wire of the remote drawer
harness together.
8) Insert the drawer cable which was disconnected
in Step 3 into the DRW1 connector, then
reassemble in the reverse order of removal.
9) Attach the ferrite core to the remote drawer cable
on the drawer side.
10) Perform the System Option Programming,
Address No. 27.
Cable Clamp
Screw (option)
Earth Wire
Ferrite Core
Remote Drawer