TD350 Series VFD Basic operation instructions
-106-
Set
value
Function
Description
32
Spindle scale-division completed
Output is valid when spindle scale-division is
completed
33
In speed limit
Output is valid when the frequency is limited
34
Virtual terminal output of
EtherCAT/PROFINET/Ethernet IP
communication
The corresponding signal is output according to
the set value of PROFINET communication.
When it is set to 1, the ON signal is output, and
when it is set to 0, the OFF signal is output.
35
Reserved
36
Speed/position control switch-over
completed
Output is valid when the mode switch-over is
completed
3740
Reserved
41
C_Y1
C_Y1 from PLC (You need to set P27.00 to 1.)
42
C_Y2
C_Y2 from PLC (You need to set P27.00 to 1.)
43
C_HDO
C_HDO from PLC (You need to set P27.00 to 1.)
44
C_RO1
C_RO1 from PLC (You need to set P27.00 to 1.)
45
C_RO2
C_RO2 from PLC (You need to set P27.00 to 1.)
46
C_RO3
C_RO3 from PLC (You need to set P27.00 to 1.)
47
C_RO4
C_RO4 from PLC (You need to set P27.00 to 1.)
4863
Reserved variables
/
Related parameter list:
Function
code
Name
Detailed parameter description
Default
value
P06.00
HDO output type
0: Open collector high-speed pulse output
1: Open collector output
0
P06.01
Y output selection
0: Invalid
1: In running
2: In forward running
3: In reverse running
4: In jogging
5: VFD fault
6: Frequency level detection FDT1
7: Frequency level detection FDT2
8: Frequency reached
9: Running in zero speed
10: Reach upper limit frequency
11: Reach lower limit frequency
12: Ready to run
13: In pre-exciting
0
P06.02
HDO output selection
0
P06.03
Relay RO1 output
selection
1
P06.04
Relay RO2 output
selection
5