TD350 Series VFD Extension cards
-309-
Definition of the state indicator
The PROFINET communication card has 9 indicators, of which LED1 is the power indicator, LEDs 2–
5 are the communication state indicators of the communication card, and LEDs 6–9 are the state
indicators of the network port.
LED2
(Bus state
indicator)
The connection to the PROFINET controller
through a network cable is OK, but the
communication is not established.
Communication with the PROFINET
controller has been established
LED3
(System fault
indicator)
PROFINET diagnosis is enabled
PROFINET diagnosis is not enabled
LED4
(Slave ready
indicator)
TPS-1 protocol stack has started
TPS-1 waits for MCU initialization
TPS-1 protocol stack does not start
LED5
(Maintenance
state indicator)
Manufacturer-specific––depending on the
characteristics of the device
LED6/7
(Network port
state indicator)
PROFINET communication card and
PC/PLC have been connected through a
network cable.
PROFINET communication card and
PC/PLC have not been connected.
LED8/9
(Network port
communication
indicator)
PROFINET communication card and
PC/PLC are communicating.
PROFINET communication card and
PC/PLC are not communicating.
Electrical connection:
The PROFINET communication card adopts a standard RJ45 interface and can adopt the linear
network topology or star network topology. The electrical connection in linear network topology mode
is shown in the following.