TD350 Series VFD Basic operation instructions
-55-
Detailed parameter description
when current motor is motor 1, only P02.06,
P02.07 and P02.08 will be autotuned; when
current motor is motor 2, only P12.06,
P12.07 and P12.08 will be autotuned.
Function parameter
restoration
0: No operation
1: Restore to default value
2: Clear fault history
Note: After the selected function operations
are done, this function code will be restored
to 0 automatically. Restoration to default
value will clear the user password, this
function should be used with caution.
0: Asynchronous motor
1: Synchronous motor
Rated power of
asynchronous motor 1
Rated frequency of
asynchronous motor 1
0.01Hz–P00.03 (Max. output frequency)
Rated speed of
asynchronous motor 1
Rated voltage of
asynchronous motor 1
Rated current of
asynchronous motor 1
Rated power of
synchronous motor 1
Rated frequency of
synchronous motor 1
0.01Hz–P00.03 (Max. output frequency)
Number of pole pairs of
synchronous motor 1
Rated voltage of
synchronous motor 1
Rated current of
synchronous motor 1
Function of multi-function
digital input terminal
(S1–S4, HDIA, HDIB)
36: Command switches to keypad
37: Command switches to terminal
38: Command switches to communication