08-09 Selection of input phase loss protection 1 : Valid
08-10 Selection of output phase loss protection 1 : Valid
11-03 Selection of reducing carrier automatically 1 : Valid
(7).
Crane
Parameter Name Optimal
00-00 Control mode selection 0 : V/F
00-05 Main Frequency Command Source Selection 0 : keypad
00-14 Acceleration time 1 3.0 sec
00-15 Deceleration time 1 3.0 sec
00-27 HD/ND Mode selection 0 : HD
11-01 Carrier frequency 5.0kHz
05-01 Frequency setting of speed-stage 0 6.0 Hz
06-01 Frequency setting of speed-stage 1 30.0 Hz
06-02 Frequency setting of speed-stage 2 60.0 Hz
03-04 Multi-function terminal Function setting-S5
2 : Multi-speed/position setting
command 1
03-05 Multi-function terminal Function setting-S6
3 : Multi-speed/position setting
command 2
03-28 Optocoupler output
23 : Source of operation
command
08-00 Stall prevention function
xx1x :
Stall prevention ineffective
in deceleration
08-09 Selection of input phase loss protection 1 : Valid
08-10 Selection of output phase loss protection 1 : Valid