EasyManua.ls Logo

TECO A510-2001-H - Group 08 Protection Function Group; 08-00 Stall prevention function

TECO A510-2001-H
311 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-27
Group 07 Start /Stop Function Group
Control mode
Code Parameter Name Range Default Unit
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
A
ttrib
ute
searching
07-22
Delay time of speed
searching
0.0~20.0 0.2 Sec O O O O O O
07-23 Voltage Recovery Time 0.1~5.0 2.0 Sec O O O O O O
0:invalid
07-24
Bidirection Speed
Search Selection
1:valid
0 - O O O X X O
07-25
Low voltage Detection
Time
0.00~1.00 0.00 Sec O O O O O O
0:invalid
07-26
Mechanical braking
selection
1:valid
0 - X X O X X O
Group 08 Protection Function Group
Control mode
Code Parameter Name Range Default Unit
V/F
V/F
+PG
SL
V
SV
PM
SV
PM
SL
V
Attrib
ute
xxx0b: Stall prevention is valid
in acceleration.
xxx1b: Stall prevention is
invalid in acceleration.
xx0xb: Stall prevention is valid
in decceleration.
xx1xb: Stall prevention is
invalid in decceleration.
x0xxb: Stall prevention is valid
in operation
x1xxb: Stall prevention is
invalid in operation
0xxxb: Stall prevention in
operation is based on
deceleration time of
speed-stage 1.
08-00
Stall prevention
function
1xxxb: Stall prevention in
operation is based on
deceleration time of
speed-stage 2.
0000b - O O O O X O
08-01
Stall prevention level in
acceleration
30~200
HD:150
ND:120
% O O O X X O
200V: 330~410 395
08-02
Stall prevention level in
decceleration
400V: 660~820 790
V O O O X X O
HD:160
08-03
Stall prevention level in
operation
30~200
ND:120
% O O O X X O
08-04 Retain