4-32
Group 11 Auxiliary Function Group
Control mode
Code Parameter Name Range Default Unit
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
Attrib
ute
0: Allow forward and reverse
rotation
1: Only allow forward rotation
11-00
Direction Lock
Selection
2:Only allow reverse rotation
0 - O O O O O O
11-01 Carrier frequency
【0】: carrier output frequency
tuning
【1】: Retain
【2~16】KHz
Determ
ined by
horse
power
(HP)
value
- O O O O O O
0: invalid
11-02
Soft PWM Function
Selection
1: valid
0 - O O O O O O
0: invalid
11-03
Automatic carrier
lowering selection
1: valid
0 - O O X X X X
11-04
S curve time setting at
the start of acceleration
0.00~2.50 0.00 s O O O O O O
11-05
S curve time setting at
the end of acceleration
0.00~2.50 0.00 s O O O O O O
11-06
S curve time setting at
the start of deceleration
0.00~2.50 0.00 s O O O O O O
11-07
S curve time setting at
the end of deceleration
0.00~2.50 0.00 s O O O O O O
11-08 Jump frequency 1
0.0~400.0
0.0~1200.0 (when 00-31 = 1 )
0.0 Hz O O O O O O
11-09 Jump frequency 2
0.0~400.0
0.0~1200.0 (when 00-31 = 1 )
0.0 Hz O O O O O O
11-10 Jump frequency 3
0.0~400.0
0.0~1200.0 (when 00-31 = 1 )
0.0 Hz O O O O O O
11-11 Jump frequency width 0.0~25.5 1.0 Hz O O O O O O
11-12
Manual energy saving
gain
0~100 80 % O O X X X X
11-13 Retain
11-14 Retain
11-15 Retain
11-16 Retain
11-17 Retain
11-18
Manual energy saving
frequency
0.00~400.00
0.0~1200.0 (when 00-31 = 1 )
0.00 Hz O X X X X X
0: Automatic energy saving is
invalid
11-19