EasyManua.ls Logo

TECO A510-2001-H - 10-03 PID control mode

TECO A510-2001-H
311 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-33
Group 11 Auxiliary Function Group
Control mode
Code Parameter Name Range Default Unit
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
Attrib
ute
11-22
A
djustment time of
automatic energy
saving
0~5000 20 ms O X X X X X *1
11-23
Detection level of
automatic energy
saving
0~100 10 % O X X X X X
11-24
Coefficient of
automatic energy
saving
0.00~655.35 - - O X X X X X
11-25 Retain
11-26 Retain
11-27 Retain
11-28 Retain
0: invalid
11-29
A
uto De-rating
Selection
1: valid
0 - O X X X X X
11-30
Variable Carrier
Frequency Max. Limit
2~16 - KHz O O X X X X
11-31
Variable Carrier
Frequency Min. Limit
2~16 - KHz O O X X X X
11-32
Variable Carrier
Frequency Proportional
Gain
00~99 00 - O O X X X X
11-33
DC Voltage Filter Rise
A
mount
0.1~10.0 0.1 Vdc O O X X X X *1
11-34
DC Voltage Filter Fall
A
mount
0.1~10.0 5.0 Vdc O O X X X X *1
11-35
DC Voltage Filter
Deadband Level
0.0~99.0 10.0 Vdc O O X X X X *1
11-36
Frequency gain of OV
prevention
0.000~1.000 0.050 - O O X X X X *1
11-37
Frequency limit of OV
prevention
0.00~10.00 5.00 Hz O O X X X X
200V: 200~400V 300
11-38
Deceleration start
voltage of OV
prevention
400V: 400~800V 700
V O O X X X X
220V: 300~400V 350
11-39
Deceleration stop
voltage of OV
prevention
440V: 600~800V 750
V O O X X X X
0: invalid
11-40
OV prevention
Selection
1: valid
0 - O O X X X X

Table of Contents

Related product manuals