4- 247
(1) Counter mode 3 is similar to the counter mode 1, with the exception that the counter value is
saved when the drive is powered down and reloaded at power up.
(2) Counter mode 4 is similar to the counter mode 2, with the exception that the counter value is
saved when the drive is powered down and reloaded at power up.
2. Timer Function
Symbol Description
Timer mode (1-7)
Timing unit
1:0.0~999.9 second
2:0~9999 second
3:0~9999 minute
Use (I1~f8) to reset timing value
ON:Internal timing value is reset and timer output is OFF
OFF:Internal timer stays running
Internal timer value
Timer set value (AS1~AS4,MD1~MD4,T1~T8,C1~C8,V1~V7,constant)
Timer output (T1 to T8, there are a total of 8 timers)