AP 3-4
CRC calculate program
UWORD ch_sum ( UBYTE long , UBYTE *rxdbuff ) {
BYTE i = 0;
UWORD wkg = 0xFFFF;
while ( long-- ) {
wkg ^= rxdbuff++;
for ( i = 0 ; i < 8; i++ ) {
if ( wkg & 0x0001 ) {
wkg = ( wkg >> 1 ) ^ 0xa001;
}
else {
wkg = wkg >> 1;
}
}
}
return( wkg );
}
Error Code
ASCII Mode RTU Mode
STX ‘:’ SLAVE Address 02H
Address
‘0’ Function 83H
1 Exception code 52H
Function
‘8’
CRC-16
High C0H
‘6’ Low CDH
Exception
code
5
1
LRC Check
2
8
END
CR
LF
During a communication error the drive will response with an Exception Code and send a
message back to the main system consisting of a Function Code that is “ANDED (and 80h)”
with 80 Hex.
Error Code Content
01 Function code error
02 Register number error
03 DATA setting error
04 Register number is over 32