3-30
6. If control mode (00-00) is set to 2 (SLV mode) and maximum frequency (01-02) is larger than
80Hz, the carrier frequency range is 2~8kHz.
The following table shows maximum output frequency for each control mode.
Duty Cycle Control Mode Other Setings Max. Output Frequency
Heavy Duty
(00-27=0)
V/F Maximum output frequency is 599Hz 599Hz
SLV
200V 1~10HP, 400V 1~15HP 150Hz
200V 15~20HP, 400V 20HP 110Hz
400V 25HP 100Hz
200V 25~40HP, 400V 30~75HP,
carrier (11-01) is set as 8K or below 8K
100Hz
200V 25~40HP, 400V 30~75HP,
carrier (11-01) is above 8K
80Hz
PMSLV
Please refer parameter group 22 of
chapter 4.3 (PM motor parameter group)
599Hz
Normal
Duty
(00-27=1)
V/F
200V 25~40HP, 400V 30~75HP
The maximum frequency is 120Hz
120Hz
SLV /PMSLV Without standard loading mode -
Model
No.
Input Voltage
(V)
Input
Current
(A)
Max. Output
Voltage (V)
Rated Output
Current (A)
Output
Power
(KW)
11-301-21-xxx-30 series
11-301-21-2P5-30 200-240 / 1Ф 8.5 240/3Ф 3.1 0.4
11-301-21-201-30 200-240 / 1Ф 12 240/3Ф 4.5 0.75
11-301-21-202-30 200-240 / 1Ф 16 240/3Ф 7.5 1.5
11-301-21-203-30 200-240 / 1Ф 23.9 240/3Ф 10.5 2.2
11-301-43-xxx-30 series
11-301-43-401-30 380-480 / 3Ф 4.2 480/3Ф 2.3 0.75
11-301-43-402-30 380-480 / 3Ф 5.6 480/3Ф 3.8 1.5
11-301-43-403-30 380-480 / 3Ф 7.3 480/3Ф 5.2 2.2
11-301-43-405-30 380-480 / 3Ф 11.6 480/3Ф 9.2 4.0
11-301-43-408-30 380-480 / 3Ф 17.0 480/3Ф 13.0 5.5
11-301-43-410-30 380-480 / 3Ф 23.0 480/3Ф 17.5 7.5
11-301-43-415-30 380-480 / 3Ф 31.0 480/3Ф 24 11
11-301-43-420-30 380-480 / 3Ф 38.0 480/3Ф 32 15
11-301-43-425-30 380-480 / 3Ф 48.0 480/3Ф 40 18.5
11-301-43-430-30 380-480 / 3Ф 48.9/63.0 480/3Ф 45/58 22/30
11-301-43-440-30 380-480 / 3Ф 65.2/78.3 480/3Ф 60/73 30/37
11-301-43-450-30 380-480 / 3Ф 81.5/95.7 480/3Ф 75/88 37/45
11-301-43-460-30 380-480 / 3Ф 98.9/112 480/3Ф 91/103 45/55
11-301-43-475-30 380-480 / 3Ф 130/159 480/3Ф 118/145 55/75
For 11-301-43-430/40/50/60/75-30, these models have two operation modes for setting.
N.D:Normal Duty operation mode.
H.D:Heavy Duty operation mode.