4-4
Setting Operations Description is as follows:
Steps
Operation
Key
LED Display Screen
after Operation
Description
1
Turn on
Power
When the power is turned on, Enter the
Status
Display Screen
.
2
Press MODE Key 4 times to enter the
System
Parameters
.
3
Press UP Key 1 time to select
Cn002
Item.
4
Press and hold the ENTER Key for 2 seconds to enter
Cn002
Setting Screen.
5
Press ENTER Key 1 time, move left to adjust the
number of digits (flashing LED).
6
Press UP Key 1 time to adjust the tens digit to 1 and
set as do not use digital input contact
CCWL
&
CWL
.
7
Press and hold the ENTER Key for 2 seconds until -
SET- appears, indicating the current set value has been
saved and after the -SET- appears once, jumps back to
the current parameter item selection screen
immediately.
Please reboot after the setting is completed. If other error alarms occur, it means the driver still
cannot function normally and users need to run troubleshooting according to “9-2 Countermeasures to
Clear Error” and operate the driver again. If the error alarm message still occurs, please contact local
distributor for further countermeasures.
4. Release Mechanical Brake:
When using the Servo Motor with Mechanical Brake, please first complete the + 24V wiring to
release the mechanical brake. If the brake is not released properly, the Trial Run will be abnormal.
5. Servo Driver Panel Operations:
Use the Servo Driver panel to operate
JOG
operations to confirm whether or not the Servo Motor
rotational speed and direction are correct. If the operating speed and direction are abnormal, please
confirm whether or not the Speed Control Parameter
Sn201
(internal Speed Command 1) and System
Parameter
Cn004
(Motor Rotation Direction Definition) are set correctly.
JOG
Operating Instructions
are as follows: