8-85 
 
8-3-6-12 Touch Probe
 
JSDG2S-E servo driver supports Touch Probe function. This function can receive the specific signal 
source during the operation, capture the position and store in the specified objects. JSDG2S-E servo 
driver supports 2 sets of Touch Probe function objects and both positive and negative edges are possible 
to set. This provides up to 4 sets of object to record the position. The supported specific signal source 
includes DI-1, DI-2 and encoder origin. 
Touch probe function (60B8h) bit  Value Description 
0 
0  Disable Touch Probe 1 
1 Enable Touch Probe 1 
1 
0  Single triggering mode 
1 Continuous triggering mode 
2,3 
0 Triggering signal is DI-1 
1 Triggering signal is the origin of encoder* 
4 
0  Disable Touch Probe1 positive edge triggering 
1  Enable Touch Probe 1 positive edge triggering 
5 
0  Disable Touch Probe1 negative edge triggering 
1  Enable Touch Probe1 negative edge triggering 
6,7 - Reserved 
8 
0  Disable Touch Probe 2 
1 Enable Touch Probe 2 
9 
0  Single triggering mode 
1 Continuous triggering mode 
10,11 0 Triggering signal is DI-2 
12 
0  Disable Touch Probe2 positive edge triggering 
1  Enable Touch Probe2 positive edge triggering 
13 
0  Disable Touch Probe2 negative edge triggering 
1  Enable Touch Probe2 negative edge triggering 
14,15 - Reserved 
ā*ā : only supports positive edge triggering