5-139
 
5-6-8 Fan Operation Settings 
The User can set the fan operation state according to the requirements, the setting is as follows: 
 
Cn031.0 Fan Operation Settings (Only Suitable to the Models equipped with Fan) 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
0  --  0 ~ 3  Effective after Confirmed  0022H 
 
Setting description:   
 
Setting  Description 
0  Temperature sensing automatic operation 
1  Operates when servo starts 
2 Continuous operation 
3 Stop operation