7-100
7-3-7 Shortcut Parameters (qn5□□)
qn501 Speed loop gain 1
6-2
Initial Value Unit Setting Range Effective Cn029 Reset
40 Hz 2 ~ 1500
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0401H --- --- O O O O --
Setting Description: Same as Sn211
qn502 Speed Loop Integration Time Constant 1
6-2
Initial Value Unit Setting Range Effective Cn029 Reset
2000 0.01ms 40 ~ 50000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0402H --- --- O O O O --
Setting Description: Same as Sn212.
qn503 Speed Loop Gain 2
6-2
Initial Value Unit Setting Range Effective Cn029 Reset
40 Hz 2 ~ 1500
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0403H --- --- O O O O --
Setting Description: Same as Sn213.
qn504 Speed Loop Integration Time Constant 2
6-2
Initial Value Unit Setting Range Effective Cn029 Reset
2000 0.01ms 40 ~ 50000
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0404H --- --- O O O O --
Setting Description: Same as Sn214.
qn505 Position Loop Gain 1
6-2
Initial Value Unit Setting Range Effective Cn029 Reset
40 rad/s 1 ~ 2000
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0405H --- --- O O O -- --
Setting Description: Same as Pn310.