5-138
 
Cn012 External Regenerative Resistor Power Setting 
Initial Value  Unit  Setting Range Effective  RS-485 Address
Default varies by driver model  W  0 ~ 10000  Effective after Confirmed  000DH 
Setting Description:  Please set the selected external resistor power value correctly in Cn012. 
Model  Initial Value 
10A / 15A / 20A / 30A  40 
50A3 / 75A3  60 
100A3 / 150A3 
10B / 15B / 25B / 35B / 50B / 75B 
100 
200A3 / 100B  200 
300A3 / 150B / 200B  0 
 
Cn089 Regenerative Resistor Resistance Setting 
Initial Value  Unit  Setting Range Effective  RS-485 Address
Default varies by driver 
model 
0.1 
ohm 
0 ~ 10000 
Effective after 
Confirmed 
005CH 
Setting Description:  Please set the resistance value of the regenerative resistor used. 
Note) Setting 0 means that regeneration is not used. 
 
 External Regenerative Resistor Wiring 
The user must prepare the Regenerative Resistor. When installing, the user must remove the 
wiring of P1 Contact and the PC Contact of TB1 terminal and then serially connect the regenerative 
resistor between P contact and PC contact. To secure personnel safety, it is recommended to use the 
Resistor with Thermal Switch. 
The wiring diagram is as follows: 
P1
PC
P
Driver
External Regenerative Resistor 
(self prepared)
TB1
Make sure the cable connecting PC and P1 
terminal is disconnected
 
Since the regenerative resistor will generate temperature higher than 100°C when consuming 
regenerative power, be sure to use heat-resistant, non-flammable wire material when connecting 
regenerative resistor, and make sure that the regenerative resistor does not make contact with any 
items.