Cn012 External Regenerative Resistor Power Setting
Initial Value Unit Setting Range Effective RS-485 Address
Default varies by driver model W 0 ~ 10000 Effective after Confirmed 000DH
Setting Description: Please set the selected external resistor power value correctly in Cn012.
Model Initial Value
10A / 15A / 20A / 30A 40
50A3 / 75A3 60
100A3 / 150A3
10B / 15B / 25B / 35B / 50B / 75B
100
200A3 / 100B 200
300A3 / 150B / 200B 0
Cn089 Regenerative Resistor Resistance Setting
Initial Value Unit Setting Range Effective RS-485 Address
Default varies by driver
model
0.1
ohm
0 ~ 10000
Effective after
Confirmed
005CH
Setting Description: Please set the resistance value of the regenerative resistor used.
Note) Setting 0 means that regeneration is not used.
External Regenerative Resistor Wiring
The user must prepare the Regenerative Resistor. When installing, the user must remove the
wiring of P1 Contact and the PC Contact of TB1 terminal and then serially connect the regenerative
resistor between P contact and PC contact. To secure personnel safety, it is recommended to use the
Resistor with Thermal Switch.
The wiring diagram is as follows:
P1
PC
P
Driver
External Regenerative Resistor
(self prepared)
TB1
Make sure the cable connecting PC and P1
terminal is disconnected
Since the regenerative resistor will generate temperature higher than 100°C when consuming
regenerative power, be sure to use heat-resistant, non-flammable wire material when connecting
regenerative resistor, and make sure that the regenerative resistor does not make contact with any