5-18
Attention
Analog speed limit input voltage has no polarity. + oltage or – voltage are received as an
absolute value. The speed limit of this absolute value is applied to forward and reverse
direction.
Even if Analog Speed limit is 0V, the Motor may rotate slowly; this is mainly caused by the minor
Offset of External Analog Voltage. In this case, the user can manually adjust Sn217 to correct the
offset or use Automatic Adjustment. Please refer to “3-3 Diagnostic Function Description”.
Attention
Please confirm the status is Servo off before adjustment; Input 0V voltage command from the
supervisory controller or external loop to analog command connect SIC (CN-1-26).
Sn217 Zero analog speed command offset adjustment
JSDG2S-E(L) does not have
this function
Initial Value Unit Setting Range Effective RS-485 Address
0 mV -2500 ~ 2500 Effective after Set 0211H
Setting Description: Used to correct offset when the Analog Speed Command Voltage generates the
offset phenomenon.
Add a filter to the analog speed command (SIC) to smooth the speed command. The analog speed
command filter is set by Sn226. When the set value is too low, the response of the speed command
may decrease. Please confirm the response while setting.
Sn226 Analog speed command filter
Initial Value Unit Setting Range Effective RS-485 Address
0 Hz 0 ~ 2500 Effective after Set 0220H
Setting Description: Set SIC analog speed command stop frequency, if set 2500, it means 2500Hz.