5-25
 
 
5-3-2 Analog speed command 
JSDG2S-E(L) does not have this function 
Adjust the slope of Voltage Command relative to the Speed Command in coordination with the 
Analog Speed Command Proportioner. 
 
Sn216 Analog speed command proportioner JSDG2S-E(L) does not have this function 
Initial Value  Unit  Setting Range  Effective  RS-485 Address
Rated Speed  rpm/10V 100 ~ 10000  Effective after Set  0210H 
Setting Description:  Used to adjust the slope of Voltage Command relative to the Speed Command. 
Setting Example: 
(1) If Sn216 is set to 3000, it means Analog Input Voltage 10V corresponds to 3000rpm Speed 
Command; if Analog Input Voltage is 5V at this time, then it corresponds to 1500rpm Speed 
Command. 
(2) If Sn216 is set to2000, it means Analog Input Voltage 10V corresponds to 2000rpm Speed 
Command; if Analog Input Voltage is 5V at this time, then it corresponds to 1000rpm Speed 
Command. 
 
Note: The displayed speed needs to be determined according to the different motors.