5-31
(3) S-type Speed Command Acceleration / Deceleration:
To use this function, Sn205.0=3 must be set to activate S-type Speed Command Acceleration /
Deceleration Function.
Sn208 S-type Speed Command Acceleration / Deceleration Time Setting (t
S
)
Initial Value Unit Setting Range Effective RS-485 Address
1 ms 1 ~ 1000 Effective after Set 0208H
Setting Description: Set Sn205.0=3 to activate S-type Speed Command Acceleration / Deceleration
Function. During Acceleration / Deceleration, due to the severe Acceleration /
Deceleration Changes when activating Stop that resulted in machine oscillation,
adding S-type Acceleration / Deceleration to Speed Command can achieve the
function of smooth operations.
Speed Command (rpm)
Time (ms)
ts ts
ta
ts
ts
td
ts=Sn208
ta=Sn209
td=Sn210
Sn209 S-type Speed Command Acceleration Time Setting (t
a
)
Initial Value Unit Setting Range Effective RS-485 Address
200 ms 1 ~ 20000 Effective after Set 0209H
Setting Description: Please refer to Sn208 Description
Sn210 S-type Speed Command Deceleration Time Setting (t
b
)
Initial Value Unit Setting Range Effective RS-485 Address
200 ms 1 ~ 20000 Effective after Set 020AH
Setting Description: Please refer to Sn208 Description
Attention! Setting Rules: ,
2
a
s
t
t
s
d
t
t
2