5-96
Cn041.2 Setting Description
Turret mode reset to zero
function
0 Does not function
1
After setting as 1, the driver will execute the turret reset
to zero function; when completed, the setting will be
cleared to 0 automatically
If other tool tower mode operations were executed without performing the calibration tool
reset to zero action, the AL.047 alarm will be generated.
Forward/reverse manual single-step mode: Under this mode, there is no need to control the digital
input contact of the tool position; one tool position will be moved every time it is triggered.
Forward Reverse
Automatic tool selection single-turn tool disc tool selection mode: This determination is
calculated by the internal software of the driver, and does not be written additionally by the
controller; also, the rotation direction will not be more than a single-turn tool disc.
For example: Current position is at tool number 1 and tool number 3 is triggered; at this time, it
will rotate forward to tool number 3;