5-114
Pn327 Tool change rotational speed 1
Initial Value Unit Setting Range Effective RS-485
100 rpm 1 ~ 2*rated rotational speed Effective after Confirmed 0323H
Setting Description: Set digital input contact TRQINV=OFF under tool magazine mode and will
change tool by the speed of tool change rotational speed 1.
Pn329 Pulse Command Smoothing Filter
Initial Value Unit Setting Range Effective RS-485 Address
0 2ms 0 ~ 2500 Power Re-set 0325H
Setting Description: Can select Filter Smoothing Time.
Pn330 Pulse Command Moving Filter
Initial Value Unit Setting Range Effective RS-485 Address
0 0.4ms 0 ~ 250 Effective after Confirmed 0326H
Setting Description: Pulse Command Moving Filter
Pn331 Turret & Tool Magazine Backlash Compensation Parameter in CCW
direction
Initial Value Unit Setting Range Effective RS-485 Address
0 pulse -8388607 ~ 8388607 Effective after Confirmed 0327H/0328H
Setting Description: Set Backlash Compensation Value
Pn332.0 Internal/External Position Command Acceleration / Deceleration Method
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 2 Effective after Confirmed 0327H/0328H
Setting Description:
Setting Description
0
Use Position Command One Time Smoothing Acceleration /
Deceleration
1
Use Internal Position Command S-type Acceleration /
Deceleration (external position command does not have this
function)
2
Use Internal Position Command S-type Acceleration /
Deceleration Separation (external position command does not
have this function)