EasyManua.ls Logo

TECO JSDG2S-100A3-E - Page 242

TECO JSDG2S-100A3-E
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-117
Setting
Description
Code Contact Operation Function
21 E-CUT
E-cam receives the cutting
completion signal
22 HS_U
U direction of HallSensor
23 HS_V
V direction of HallSensor
24 HS_W
W direction of HallSensor
25
E-STOPI
N
E-cam temporarily stopped
26 gantryDI
Gantry simultaneous action DI
trigger is out of sync
27 KSPD
Second stage speed of turret
28 MDC3
Control mode selection 3 in tool
magazine mode
29 DI_Jog_1
JOG function selection 1
2A DI_Jog_2
JOG function selection 2
2B MDC4
Control mode selection 4 in tool
magazine mode
2C KTI1
Turret input 1
2D KTI2
Turret input 2
Hn601.2~ Hn612.2 DI-1~ DI-12 Pin Function Operation Potential
Initial Value Unit Setting Range Effective RS-485 Address
Change with Mode -- 0 ~ 1 Power Re-set Please refer to Parameter Description
Setting Description:
Setting Description
0 When the pin is closed, the function activates.
1 When the pin is open, the function activates.
Attention
DI-1~DI-12 Pin Functions can be repeated, but the pin operating potential of repeated
function must be the same, otherwise it will generate AL007 alarm (digital input/output
contact function planning error alarm).
When DI-1~DI-12 pin functions are repeated, pin function is determined by OR (or gate)
method
Multifunction Planning Digital Input Contact Default Value
DI
Code
Input
Function
0
T
1
S
2
Pe
3
Pe
S
4
S
T
5
Pe
T
6
Pi
7
Pi
S
8
Pi
T
9
Pt
A
Pi
Pe
B
Cob
C
CoC
D
EC
E
Pt
00 NULL
DI1
DI8
~
DI12
DI1
DI8
~
DI12
DI1
DI2
DI8
~
DI12
01 SON DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI9

Table of Contents