5-141
The User can set the Low Voltage Protection Automatic Reset Function according to the
requirements, the setting is as follows:
Cn031.1 Low voltage protection (AL001) automatic return selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Effective after Confirmed 0022H
Setting Description: This parameter can set low voltage protection (AL001) return method
Setting Description
0
When SON status shows run, AL001 Low Voltage
Error Alarm is immediately displayed when a low
voltage is detected; after the Error is resolved, it
must be restored in Soff status.
1
When the SON status displays “run”, BB status is
immediately displayed when a low voltage is
detected; and automatically resets to SON status
and displays “run” after the Error is resolved.