5-151
Pn346.1 Full-closed loop origin signal source selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Power Re-set 0337H
Setting Description:
Setting Description
0 Servo motor encoder
1 External encoder
Pn346.2 Full-closed loop function dividing selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Power Re-set 0337H
Setting Description:
Setting Description
0 Eencoder
1 Full-closed loop
Pn346.3 Full-closed loop function speed feedback selection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Power Re-set 0337H
Setting Description:
Setting Description
0 Encoder
1 Full-closed loop
Pn347 Maximum full-closed loop error
Initial Value Unit Setting Range Effective RS-485 Address
5000 pulse 0 ~ 536870912 Effective after Set 0338H/0339H
Setting Description: External encoder and actual encoder error setting value. When the position error
is greater than the pulse number set by Pn347, this device generates AL.022
(excessive pulse error between motor and load)
Pn348 Corresponded resolution of Full-closed loop Encoder one circle
Initial Value Unit Setting Range Effective RS-485 Address
1250 ppr 256 ~ 1048576 Power Re-set 0338H/0339H
Setting Description: The number of pulses corresponding to the external optical ruler when the motor