5-163
 
EC922 Enable E-Cam parameter change write-in 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
0  -  0 ~ 1 
Effective after Confirmed 
081EH 
Setting Description:  Set this parameter as 1 when changing the parameter to enable parameter change. 
 
EC923 E-Cam parameter fine-tune factor 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
10000  0.01  0 ~ 65535 
Effective after Confirmed 
081FH 
Setting Description:  Fine-tune the cutting length to correct machine error. 
 
EC924.0 E-Cam rotary cut return origin return function 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
0  -  0 ~ 1 
Effective after Confirmed 
0820H 
Setting Description:   
Setting  Description 
0 Original curve 
1  Return to Origin 
 
Pn349 Full-closed loop operation direction setting 
Initial Value  Unit  Setting Range  Effective  RS-485 
0  --  0 ~ 1  Power Re-set  033CH 
Setting Description:  It is necessary to consider main axle feedback direction when choosing the 
physical main axle. AL.023 will occur when the direction is incorrect. 
 
Setting  Description 
0  Phase A leading phase B 