7-95
Pn360 INP and tool number output delay time of Turret & Tool magazine
Initial Value Unit Setting Range Effective Cn029 Reset
0 1ms 0 ~ 10000
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
034CH -- -- -- -- O -- --
Setting Description: When entering the INP condition and continuously meeting the set time, INP and tool number will be
output.
Pn361 Sensorless origin reset torque limit value
Initial Value Unit Setting Range Effective Cn029 Reset
30 % 0 ~ 100
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
034DH -- -- O O O -- --
Setting Description: Used when Pn317 = 6~9; when the top reaches the setting value of Pn361 and continues for the time
of Pn362, origin reset is completed.
Pn362 Sensorless origin reset torque stabilization continuous time
Initial Value Unit Setting Range Effective Cn029 Reset
1500 1ms 0 ~ 10000
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
034EH -- -- O O O -- --
Setting Description: Used when Pn317 = 6~9; when the top reaches the setting value of Pn361 and continues for the time
of Pn362, origin reset is completed.
Pn378 Turret parameter 1
Initial Value Unit Setting Range Effective Cn029 Reset
300 4ms 1 ~ 2500
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
035EH -- -- -- -- O -- --
Setting Description: Turret parameter 1.