EasyManua.ls Logo

TECO JSDG2S-100A3-E - Page 513

TECO JSDG2S-100A3-E
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-8
Hn623 Digital output contact control method selection
5-6-1
Initial Value Unit Setting Range Effective RS-485 Address
H’0000 --
H0000 ~ H0FFF
(Hexadecimal)
Effective after Set 0517H
Setting description: Uses bit setting method to determine the contact output status of thedigital output,
binary to hexadecimal conversion is used for the bit setting; first, correspond DO-01 ~ DO-
08 to the binary 1 ~8 bits, and then plan the setting after converting binary bits into
hexadecimal
Binary bit representation: 0: Use the function setting to determine DO ON or OFF
1: Use the communication setting to determine DO ON or OFF
Hn624 Communication control digital output contact status5-6-1
Initial Value Unit Setting Range Effective RS-485 Address
H’0000 --
H0000 ~ H0FFF
(Hexadecimal)
Effective after Set 0518H
Setting description: Uses bit setting to determine the contact status when communication is used to
control the communication control digital output contact; please refer to the
descriptions for Hn623 for the bit setting methods
Binary bit representation: 0: Digital output contact OFF
1: Digital output contact ON

Table of Contents

Related product manuals