AL.015 Driver Overheat CiA402 Error Code 0x4210-08-0015
Alarm Cause
Detected the Power Transistor Temperature exceeded the Temperature Resistance
of the Component.
1. Continuous use with excessive motor rated load.
2. Ambient temperature too high.
3. The installation director of the servo unit and its spacing between other servo
units are not reasonable.
4. Driver fan stops operation.
Check and
Handling
1. Increase motor capacity or decrease load.
2. Decrease ambient temperature.
3. Follow installation standard of the servo unit to install.
4. Remove any foreign object that jams the fan; replace the fan when it cannot
function correctly.
Alarm Clearing
Method
Switch Reset
AL.016
Absolute Type Encoder Number of
Revolution Error
CiA402 Error Code 0x7305-01-0016
Alarm Cause
Absolute Type Encoder Number of Revolution Data Error.
1. Battery module is removed or battery error.
2. Replace the battery when the driver power is off.
Check and
Handling
1. Please check battery wiring and power.
2. After the battery is replaced, use Cn041=2 or digital input contact ALRS to clear
the rotation number of the encoder.
Alarm Clearing
Method
Switch Reset
AL.017 MCU Error 1 CiA402 Error Code 0x6100-80-0017
Alarm Cause System Operating Error Self Checking Error during System Operations.
Check and
Handling
Please contact Dealer or Manufacturer
Alarm Clearing
Method
Power Re-set
AL.018 MCU Error 2 CiA402 Error Code 0x6100-80-0018
Alarm Cause System Operating Error Self Checking Error during System Operations.
Check and
Handling
Please contact Dealer or Manufacturer
Alarm Clearing
Method
Power Re-set