EasyManua.ls Logo

TECO JSDG2S-100A3-E - Page 683

TECO JSDG2S-100A3-E
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-22
AL.060
EtherCAT synchronization signal
abnormal
CiA402 Error Code 0xff00-80-0060
Alarm Cause
Signal interference or hardware damage.
Check and
Handling
1. Confirm the hardware wiring and cables.
2. If the alarm still occurred during operation after reconnecting the power, confirm
whether the driver is damaged. (Please consult the dealer or the manufacturer).
Alarm Clearing
Method
Switch reset
AL.061
Regenerative parameter setting
error
CiA402 Error Code 0x6320-80-0061
Alarm Cause
Parameter setting error.
Check and
Handling
1. Confirm the hardware wiring and cables.
2. If the alarm still occurred during operation after reconnecting the power, confirm
whether the driver is damaged. (Please consult the dealer or the manufacturer).
Alarm Clearing
Method
Switch reset
AL.062 Servo excitation instruction invalid CiA402 Error Code 0xff04-80-0062
Alarm Cause
When the driver has dynamic brakes, Son signal is sent to the motor while it is
rotating
Check and
Handling
Send to the Son signal when the motor is under 20rpm
Alarm Clearing
Method
Switch reset
AL.063 Mapping parameter setting error CiA402 Error Code 0xff04-80-0063
Alarm Cause
Map parameter address (MAb group) parameter setting error
Check and
Handling
Please refer to the MAb01~08 setting description.
Alarm Clearing
Method
Switch reset, reset parameter
AL.064 Software limit setting error CiA402 Error Code 0xff04-80-0064
Alarm Cause
Software limit setting error
Check and
Handling
Please refer to the Pn357 and Pn358 setting descriptions.
Alarm Clearing
Method
Switch reset

Table of Contents