3-4
Steps
Operation
Key
LED Display Screen
after Operation
Description
17
Press MODE Key once to enter
Status Display
Screen
. Cycle through in sequence.
※
Can be modified Cn035 to monitor parameters.
§Monitoring display when power is turned on
By setting Cn035 (panel status display content selection), the display content after power-on can be
set to monitor parameter (Un-□□) display instead of the status display screen.
Cn035 Panel status display content selection
Initial
Value
Unit Setting Range Effective RS-485 Address
0 -- 0 ~ Un parameter maximun
Effective
after setting
0026H
Setting description:
Setting Description
This parameter can set the panel status display content after power-on
0
Display bit data and status code, please refer to [3-1 Driver Panel Operation
Instructions]
1 ~ Maximun
To display the contents of the Un status display parameters, please refer to [7-3-
12 Monitoring Parameters].
Example: When Cn035=1, the actual motor speed (Un-01 content) will be
displayed on the panel after power is turned on.