4-23
00-12
Frequency Upper limit
Range
0.01~599.00Hz
00-13
Frequency Lower limit
Range
0.00~649.99Hz
Stpo” is displayed on the keypad when RUN is pressed and parameter 00-13 and the command frequency
are both set to 0.00.
When Frequency command is greater than 00-13 the inverter output will ramp up from 0.00 to the command
frequency.
When 00-13 is greater than 0, and the frequency command value smaller or equal to 00-13, the inverter
output will ramp up to the lower limit frequency set by 00-13.
Frequency
Reference
Output
Frequency
100%
00-12
00-13
100%
00-14
Acceleration time 1
Range
0.1~3600.0s
00-15
Deceleration time 1
Range
0.1~3600.0s
00-16
Acceleration time 2
Range
0.1~3600.0s
00-17
Deceleration time 2
Range
0.1~3600.0s
Acceleration time is the time required to accelerate from 0 to 100% of maximum output frequency.
Deceleration time is the time required to decelerate from 100 to 0% of maximum output frequency.
Preset Acceleration and Deceleration times by above parameters are the time taken for the output frequency
to ramp up or ramp down between the Upper and the lower frequency limits.
Actual acceleration and deceleration time is calculated as follows
(00-15) X (set frequency - the minimum starting frequency)
Actual acceleration time=
(00-14) X (set frequency - the minimum starting frequency)
Maximum output frequency
Actual deceleration time=
Maximum output frequency