4-49
SLV mode:
Actual Acc time=
Time of Accel1 or 2 x Preset Frequency
Motor rated output frequency
Actual Dec time=
Time of Accel1 or 2 x Preset Frequency
Motor rated output frequency
V/F Maximum output frequency set by parameter 01-02 when custom V/F is selected by 01-00 =7.
V/F Maximum output frequency = 50.00 Hz or 60.00 Hz when preset V/F patterns are selected. 01-00 =1 to 6.
Preset speed 1 Actual Accel time=
(05-19) X 10(Hz)
01-02
Example01- 007, 01- 02=50Hz, 05- 02=10Hz (preset speed1),
05-19=5s(Accel time), 05-20=20s (Decel time)
= 1(s)
Preset speed 1 Actual Deccel time=
(05-20) X 10(Hz)
01-02
= 4(s)
Multi speed run/stop cycles with Individual accel/decel times. 05-00=1
Two modes of operation:
Mode1 = On/Off run command
Mode2 = Continuous run command
Mode1 Example: 00-02=1(External Run/Stop Control).
00-04=1(Operation ModeRun/stop-forward/reverse).
S1: 03-00=0(RUN/STOP );
S2: 03-01=1(Forward/Reverse);
S3: 03-02=2(Preset speed 1);
S4: 03-03=3(Preset speed 2);
S5: 03-04=4(Preset speed 4);
Acceleration / Deceleration Calculation Mode 1:
If the run command is cycled on and off, acceleration and deceleration time (a ~ f) is calculated based on the
active speed command as follows: