4-31
00- 05
Main Frequency Command Source Selection
00- 06 Alternative Frequency Command Source Selection
Range
0:UP/DOWN of Keypad
1:Potentiometer on Keypad
2:External AVI Analog Signal Input
3:External ACI Analog Signal Input
4:External Up/Down Frequency Control
5:Communication setting Frequency
6:PID Output frequency
When 00-06 =[6], frequency command source is output of the PID.
00- 07 Main and Alternative Frequency Command Modes
Range
0:Main Or Alternative Frequency.
1:Main frequency + Alternative Frequency
When 00-07=0, the frequency source is set by the Main frequency parameter 00-05
(Default) or by the Alternative frequency parameter 00-06. Use any of the external terminals
S1 to S5 and set the relevant parameter 03-00 to 03-04 =13to switch from main to
Alternative source.
When 00 - 07 =1The Frequency command will be the result of setting of Main & alternative
frequencies.
00- 08 Communication Frequency Command
Range
0.00~599.00Hz
This parameter can be used to read the set frequency in communication mode
This parameter is only effective in the communication mode.
00- 09 Frequency Command save on power down (Communication mode)
Range
0:Disable
1:Enable
00-09=0 Keypad frequency is saved.
00-09=1 Frequency set by communication is saved.
00-10 Initial Frequency Selection
Range
0:By Current Frequency Command
1:By Zero Frequency Command
2:By 00-11
00-11 Initial Frequency Set point
Range
0.00~599.00Hz
This parameter is only effective in keypad mode..
When 00-10=0,the initial frequency will be current frequency.
When 00-10=1,the initial frequency will be 0.
When 00-10=2,the initial frequency will be as set by parameter 00-11.