4-49
03-16
Fixed
Value
100msec
03-15
03-11
ON
I load
100%
T
03-17
Brake Release Level
Range
0.00~20.00 Hz
03-18
Brake Engage Level
Range
0.00~20.00 Hz
If 03-11 =14
In accelerating mode. RY1 will be ON as soon as the actual output frequency reaches the
external Brake release level set in parameter 03-17.
In decelerating mode, RY1 will be OFF as soon as the actual output frequency reaches the
external Brake engage level set in parameter 03-18.
Timing diagram for 03-17 < 03-18 is shown below:
03-17
03-18
03-11=14
RUN command
Hz
T
ON OFF
RUN STOP
Timing diagram for 03-17 > 03-18 is shown below: