MANUAL CHANGE INFORMATION
Product 2205 SERVICE Date: 8-23-91 Change Reference: M73789(RevY
DESCRIPTION Product Group 46
DIAGRAM CHANGES
DIAGRAM POW ER SUPPLY
Remove C932 (location 5E) and add A6 Frequency Stabili2ing Circuit Board to power supply:
Connect J901 -1 to + hole where C932 was previously installed.
Connect J901-2 to - hole (ground) where C932 was previously installed on A1.
Connect W301 to U930 pin 5 (location 7F).