Command Groups
Command
Description
WFMOutpre:BN_Fmt Sets or returns the format of the binary data
encoding of the waveform to b e transferred
from the instr
ument
WFMOutpre:B
YT_Nr?
Returns the b
yte width for the waveform to
be transferred from the instrument
WFMOutpre:BYT_Or Sets or returns which byte of binary waveform
data is transmitted first during a waveform
data transf
er
WFMOutpre
:ENCdg
Sets or ret
urns the type of encoding used for
waveform data transferred with the CURVe?
command
WFMOutpre:NR_Pt? Returns the number of points that were
returned
by the previous CURVe? command
WFMOutp
re:PT_Fmt?
Returns
the data point format of the
waveform returned by the previous CURVe?
command
WFMOutpre:WFId? Returns a descriptive string of the waveform
return
ed by the previous CURVe? command
WFMOu
tpre:WFMLabel?
Retur
ns the label for the previous waveform
transferred by the CURVe? command
WFMOutpre:XINcr? Returns the interval between samples of
the waveform transferred by the CURVe?
comm
and
WFMO
utpre:XMUlt?
Retu
rns the horizontal scale factor of the
waveform returned by the previous CURVe?
command
WFMOutpre:XOFf?
Returns the horizontal position in horizontal
units of the returned waveform
WFMOutpre:XUNit? Returns the horizontal units of the waveform
re
turned by the previous CURVe? command
W
FMOutpre:XZEro?
R
eturns the time of first point (sample) of the
waveform returned by the previous CURVe?
command
WFMOutpre:YMUlt? Returns the vertical scale factor in vertical
units per division of the waveform r eturned
by the previous CURVe? command
WFMOutpre:YOFf? Returns the vertical position of the waveform
returned by the previous CURVe? command
WFMOutpre:YSCALE? Returns vertical unit scale factor of the
incoming waveform by the previous CURVe?
command
WFMOutpre:YUNit? Returns the vertical units of the waveform
returned by the previous CURVe? command
WFMOutpre:YZEro? Returns the vertical offset of the waveform
returned by the previous CURVe? command
DSA/CSA/TDS8X00/B Series Programmer Manual 2-49

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DSA8200 Series and is the answer not in the manual?

Tektronix DSA8200 Series Specifications

General IconGeneral
BrandTektronix
ModelDSA8200 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals