Appendix H: List of Beta Commands and Features
AFG:TRIGger:
MODe
Description:
Sets the operating trigger mode for the AFG.
Conditions:
Beta Command, see conditions of use. Default setting is NONe.
Group:
AFG
Syntax:
AFG:TRIGger:MODe {NONe|BURst}
AFG:TRIGger:MODe?
Arguments:
NONe - No special trigger mode.
BURst - Burst mode, set in conjunction with AFG:RUNMode BURst.
Examples:
AFG:TRIGger:MODe BURst sets the trigger mode to BURst.
AFG:TRIGger:POLarity
Description:
Sets the trigger edge polarity for the AFG. Only applicable for when
AFG:TRIGger:SOUrce
is EXTernal.
Conditions:
Beta Command, see conditions of use.Default
setting is POSitive.
Group:
AFG
Syntax:
AFG:TRIGger:POLarity {POSitive|NEGative}
AFG:TRIGger:POLarity?
Arguments:
INTERNal - Trigger uses internal AFG source.
EXTernal - External trigger, connected to the scope main trigger signal.
Examples:
AFG:TRIGger:POLarity POSitive sets the trigger source to POSitive.
AFG:TRIGger:SOUrce
Description:
Sets the trigger source for the AFG.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual H-9