Command Descriptions
TDS200, TDS1000/2000, TDS1000B/2000B, TPS2000 Programmer
2- 137
HORizontal:DELay:SECdiv
This command is identical to the HORizontal:DELay:SCAle. It is
provided to maintain program compatibility with some older models
of Tektronix oscilloscopes.
HORizontal:MAIn? (Query Only)
Returns all settings for the oscilloscope main time base . The
HORizontal:MAIn:SECdiv and HORizontal:MAIn:SCAle com-
mands are identical so only HORizontal:MAIn:SCAle is returned.
Horizontal
HORizontal:MAIn?
All settings for the main time base.
HORizontal:MAIn?
Might return :HORIZONTAL:MAIN:POSITION 0.0E0;SCALE 5.0E–4
HORizontal:MAIn:POSition
Sets or queries the main time base horizontal position. This
command is equivalent to adjusting the Horizontal Position when
Main is selected from the Horizontal menu.
Horizontal
HORizontal:MAIn:POSition <NR3>
Group
Syntax
Returns
Examples
Group