Command Descriptions
TDS200, TDS1000/2000, TDS1000B/2000B, TPS2000 Programmer
2-67
ON inverts the specified oscilloscope channel.
OFF sets the specified oscilloscope channel to non-inverted.
CH1:INVert ON
Inverts the signal on channel 1.
CH2:INVert?
Might return OFF, indicating that channel 2 is not inverted.
CH<x>:POS ition
Sets or queries the vertical position of the specified oscilloscope
channel. The value of <x> can vary from 1 through 4 for 4-channel
instruments or 1 through 2 for 2-channel instruments.
The position voltage value is applied to the signal before digitiza-
tion. This command is equivalent to adjusting the front-panel
VERTICAL POSITION knob.
Vertical
CH<x>:POSition <NR3>
CH<x>:POSition?
<NR3> is the position in divisions from the center graticule.
Table 2--28 lists the vertical position ranges using a 1X probe.
Arguments
Examples
Group
Syntax
Arguments

Table of Contents