Field Description
Possible values:
• E-mail
• SMS
Recipient Enter the recipient's e-mail address. The entry is limited to 40
characters.
Message Compression
Select whether the text in the alert E-mail is to be shortened.
The e-mail then contains the syslog message only once plus the
number of relevant events.
Enable or disable the field.
The function is enabled by default.
Subject
You can enter a subject.
Event
This feature is available only for devices with Wireless LAN
Controller.
Select the event to trigger an email notification.
Possible values:
• *&#, "# # (default value): A Syslog mes-
sage includes a specific string.
• '1 '  - !3: A new adjacent AP has been
found.
• '1 @ 3 - !3: A new Rough AP has been found,
i.e. an AP using an SSID of its own network, yet is not a com-
ponent of this network.
• '1 *, - 8( !3: A new unconfigured AP has
reported to the WLAN.
• %  - !!,: A managed AP is no longer access-
ible.
Matching String
You must enter a "Matching String". This must occur in a syslog
message as a necessary condition for triggering an alert.
The entry is limited to 55 characters. Bear in mind that without
the use of wildcards (e.g. "*"), only those strings that correspond
exactly to the entry fulfil the condition. The "Matching String"
Teldat GmbH
23 External Reporting
bintec Rxxx2/RTxxx2 521

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Teldat bintec R3002 and is the answer not in the manual?

Teldat bintec R3002 Specifications

General IconGeneral
BrandTeldat
Modelbintec R3002
CategoryGateway
LanguageEnglish

Related product manuals